The Tenor 16-bits Data Logger is an 8-channel data logger system dedicated to acoustic and vibration measurements.
Based on DSP technology, the Tenor allows the simultaneous acquisition and storage of 8 channels on a PC
through a high speed USB 2 link.
The Tenor 24-bits Data Logger is an 8-channel input and 4-channel output data logger system dedicated to
acoustic and vibration measurements. Based on DSP technology, the Tenor 24-bits allows the simultaneous acquisition and
storage of all channels on a PC through a high speed USB 2 link.
16-Bits version
|
24-Bits version
|
|
|
HARDWARE TECHNICAL DATA
- Sampling rate up to 43 kHz per channel for 8 channels
- SNR: 85 dB (input) and 88 dB (output)
- Dynamic range: 110 dB
- 4 input types: Direct DC, Direct AC, ICP and Electret
- Input dynamic range (+/-25 mV to +/-5 V)
- 8 independant programmable analog outputs with LED status
- Output dynamic range (+/-2V)
- Anti-aliasing filter on outputs and inputs
- BNC connector with LED status for each input and ouput
- 24Volt-0,5A External AC/DC power supply included
- Dimensions (WxHxD): 77 x 217 x 274 mm (3 x 8 1/2 x 10 3/4 inches)
- Weight: 2.4 kg (5.2 lbs)
|
HARDWARE TECHNICAL DATA
- Eight 24-bits analog inputs and four 24-bits analog outputs
- Sampling rate: 48.8 kHz per channel for 8 inputs
- SNR: 105 dB (input and output)
- 2 input types: ICP, Direct DC, Direct AC
- Input dynamic range: ±4.5V
- Output dynamic range: ±2V
- Anti-aliasing filter on outputs and inputs
- LED status light on each input and output
- External Power Supply: 12 VDC power pack included
- Dimensions (WxHxD): 77 x 217 x 274 mm (3 x 8½ x 10¾ in.)
- Weight: 2.4 kg (5.2 lb)
|
SOFTWARE TECHNICAL DATA
- Data-logging in a standard .wav file format
- Sensor calibration module and management of a sensor bank
- Real time dynamic and saturation monitoring of 8 input channels
- Real time monitoring of input and output signals (time signal, global levels historic and average Sxx)
- Complete post-processing module
- Wave file generation module
|
SOFTWARE TECHNICAL DATA
- Real-time acquisition/data-logging for 8 inputs simultaneously
- Sensor calibration module and management of a sensor bank
- Complete post-processing module
- Data-logging in a standard .wav file format
- Real-time monitoring of input and output signals (time signal, global levels historic and average Sxx)
- Real-time dynamic and saturation monitoring of 8 input channels
- Real-time signal generator on 4 outputs (sine wave, square wave, white noise, impulse, periodic random noise and more)
|
DOWNLOAD
|
DOWNLOAD
|
Quick link:
-ACQUISITION MODULE
-POST PROCESS MODULE
ACQUISITION MODULE
 |
Acquisition and Monitoring
- Real time monitoring of time signal, global levels history and Sxx (Leq or exponential average)
- Dynamic range and saturation indicators on all 8 inputs
- Monitoring of saturation percentage on all 8 inputs
- Instantaneous global levels monitoring on all 8 inputs
|
 |
Instrument Set-up
- Visual selection and input/output configuration
- Management of a sensor bank for a quick set-up of the inputs
- Save and recall of the entire configuration of the instrument
|
 |
Wave File Generation Module
- Easy to use interface to generate wave file for output log
- Various signal types: Sine, Triangular, Square, Saw tooth, Uniform White Noise, Gaussian White Noise, Periodic Random noise, Impulse pattern
|
 |
Sensor Calibration Module
- Calibration module to automatically determine the sensitivity of a sensor
- Adjustable frequency and level for the calibrator
|
POST PROCESSING MODULE
Note : This module can be used without the harwdare unit. Use the free software download to test post- processing functions.
 |
Post-Processing Main Interface
- Various analysis functions: global levels history, average FFT, statistics, waterfall, FRF and ISO 2631
- Filtering and time integration operations
- Signal extraction to allow removing a saturated portion of the signal
- Playback function to listen to a specific portion of a selected channel
- Export functions in a single .wav or a .txt file
|
 |
Average Sxx Function
- Compute the average Sxx of the entire signal with a user selectable overlap and time window
- FFT number of lines from 1024 to 8192
- Simple or double integration
- Linear, dB and dB(A)
|
 |
Statistical Function
- Compute the standard L% statistics of the global levels
- User selectable time step
- Simple or double integration
- Linear, dB and dB(A)
|
 |
Global Levels Historic
- Compute the global levels history
- User selectable time step
- Simple or double integration
- Linear, dB and dB(A)
|
 |
Waterfall Function
- Shows the instantaneous Sxx over time
- User selectable overlap and time window
- FFT number of lines from 1024 to 8192
- Linear, dB and dB(A)
- Simple or double integration
- 3D rotation and zoom
|
 |
FRF Function
- Computes H1, H2 or H3 for two selectable inputs
- Amplitude, phase, and coherence graphs
- User selectable overlap and time window
- FFT number of lines from 1024 to 8192
- Linear, dB and dB(A)
|
 |
Filtering Function
- Various type of filters: ButterWorth, Chebyshev, Inv. Chebyshev, Elliptic and Bessel
- Lowpass, Highpass, Bandpass or Bandstop filter
|
*Prices are subject to change without notice.
For prices and info, e-mail us at Order
|